Skip to main content
.141 Coaxial Cable – 50 Ω Flexible Jacketed SPC Braid over SPF – Non-Magnetic

EZ-FLEX.402-CU

© EZ Form Cable Inc. All rights reserved.

⌀.141" Flexible SPC Braid over SPF Outer Conductor, SPC Center Conductor, PTFE Dielectric, Blue FEP Jacket, 50 Ω. Non-Magnetic.

Specifications

Dimensions

  • Center Conductor Diameter
    0.0360 in
  • Dielectric Diameter
    0.1170 in
  • Outer Conductor Diameter
    0.1410 in
  • Jacket Diameter
    0.1600 in

Materials

  • Center Conductor Material
    SPC
  • Dielectric Material
    PTFE
  • Outer Conductor Material
    SPC Braid over SPF
  • Jacket Material
    Blue FEP
  • RoHS Compliant
    Yes

Mechanical Characteristics

  • Minimum Temperature
    −55 °C
  • Maximum Temperature
    +200 °C
  • Inside Bend Radius (Minimum)
    0.500 in
  • Weight
    3.00 lbs
    per 100 ft

Electrical Characteristics

  • Nominal Impedance
    50.0 Ω
  • Nominal Impedance Margin
    ±1.0 Ω
  • Velocity of Propagation
    70.00%
  • Shielding Effectiveness
    >100 db
  • Voltage Withstanding
    5000 VRMS
    @ 60 Hz
  • Continuous Working Voltage
    2000 VRMS
    max
  • Maximum Operating Frequency
    34 GHz
Attenuation
Frequencydb / 100 Ft Typical
0.5 GHz
7.6 db
1.0 GHz
11.1 db
5.0 GHz
28.1 db
10.0 GHz
43.4 db
18.0 GHz
63.6 db
26.5 GHz
82.8 db
Power
FrequencyWatts CW @ 20 °C (Max)
0.5 GHz
600 W
1.0 GHz
450 W
5.0 GHz
180 W
10.0 GHz
120 W
18.0 GHz
73 W
26.5 GHz
70 W

.141 Coaxial Cable – 50 Ω Flexible Jacketed SPC Braid over SPF – Non-Magnetic

EZ-FLEX.402-CU

⌀.141" Flexible SPC Braid over SPF Outer Conductor, SPC Center Conductor, PTFE Dielectric, Blue FEP Jacket, 50 Ω. Non-Magnetic.

feet
Add to Quote

Truly flexible high-performance cable, EZ-Flex 401, 402, and 405 have performance comparable to MIL-DTL-17 semi-rigid, yet handle like RG flexible cables and offer:
• Low leakage
• Low VSWR
• True flexibility
• High durability
• Lower weight
These cables are designed to be used with standard connectors for semi-rigid cable.

See more:

Specifications

Dimensions

  • Center Conductor Diameter
    0.0360 in
  • Dielectric Diameter
    0.1170 in
  • Outer Conductor Diameter
    0.1410 in
  • Jacket Diameter
    0.1600 in

Materials

  • Center Conductor Material
    SPC
  • Dielectric Material
    PTFE
  • Outer Conductor Material
    SPC Braid over SPF
  • Jacket Material
    Blue FEP
  • RoHS Compliant
    Yes

Mechanical Characteristics

  • Minimum Temperature
    −55 °C
  • Maximum Temperature
    +200 °C
  • Inside Bend Radius (Minimum)
    0.500 in
  • Weight
    3.00 lbs
    per 100 ft

Electrical Characteristics

  • Nominal Impedance
    50.0 Ω
  • Nominal Impedance Margin
    ±1.0 Ω
  • Velocity of Propagation
    70.00%
  • Shielding Effectiveness
    >100 db
  • Voltage Withstanding
    5000 VRMS
    @ 60 Hz
  • Continuous Working Voltage
    2000 VRMS
    max
  • Maximum Operating Frequency
    34 GHz
Attenuation
Frequencydb / 100 Ft Typical
0.5 GHz
7.6 db
1.0 GHz
11.1 db
5.0 GHz
28.1 db
10.0 GHz
43.4 db
18.0 GHz
63.6 db
26.5 GHz
82.8 db
Power
FrequencyWatts CW @ 20 °C (Max)
0.5 GHz
600 W
1.0 GHz
450 W
5.0 GHz
180 W
10.0 GHz
120 W
18.0 GHz
73 W
26.5 GHz
70 W
Attenuation
Frequencydb / 100 Ft Typical
0.5 GHz
7.6 db
1.0 GHz
11.1 db
5.0 GHz
28.1 db
10.0 GHz
43.4 db
18.0 GHz
63.6 db
26.5 GHz
82.8 db
Power
FrequencyWatts CW @ 20 °C (Max)
0.5 GHz
600 W
1.0 GHz
450 W
5.0 GHz
180 W
10.0 GHz
120 W
18.0 GHz
73 W
26.5 GHz
70 W
.141 Coaxial Cable – 50 Ω Flexible Jacketed SPC Braid over SPF – Non-Magnetic
feet
Add to Quote
EZ Form Cable
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.