Skip to main content
.141 Coaxial Cable – 50 Ω Formable Jacketed Copper-Tin Composite – Non-Magnetic

EZ-FLEX.141-CU-J

© EZ Form Cable Inc. All rights reserved.

⌀.141" Formable Copper-Tin Composite Outer Conductor, SPC Center Conductor, PTFE Dielectric, Blue FEP Jacket, 50 Ω. Non-Magnetic.

Specifications

Dimensions

  • Center Conductor Diameter
    0.0360 in
  • Dielectric Diameter
    0.1170 in
  • Outer Conductor Diameter
    0.1410 in
  • Jacket Diameter
    0.1600 in

Materials

  • Center Conductor Material
    SPC
  • Dielectric Material
    PTFE
  • Outer Conductor Material
    Copper-Tin Composite
  • Jacket Material
    Blue FEP
  • RoHS Compliant
    Yes

Mechanical Characteristics

  • Minimum Temperature
    −55 °C
  • Maximum Temperature
    +200 °C
  • Inside Bend Radius (Minimum)
    0.375 in
  • Weight
    2.10 lbs
    per 100 ft

Electrical Characteristics

  • Nominal Impedance
    50.0 Ω
  • Nominal Impedance Margin
    ±1.0 Ω
  • Velocity of Propagation
    70.00%
  • Shielding Effectiveness
    >90 db
  • Voltage Withstanding
    5000 VRMS
    @ 60 Hz
  • Continuous Working Voltage
    2000 VRMS
    max
  • Maximum Operating Frequency
    34 GHz
Attenuation
Frequencydb / 100 Ft Typical
0.5 GHz
8.4 db
1.0 GHz
12.2 db
5.0 GHz
30 db
10.0 GHz
46 db
18.0 GHz
67.6 db
26.5 GHz
87.2 db
Power
FrequencyWatts CW @ 20 °C (Max)
0.5 GHz
600 W
1.0 GHz
450 W
5.0 GHz
180 W
10.0 GHz
120 W
18.0 GHz
73 W
26.5 GHz
70 W

.141 Coaxial Cable – 50 Ω Formable Jacketed Copper-Tin Composite – Non-Magnetic

EZ-FLEX.141-CU-J

⌀.141" Formable Copper-Tin Composite Outer Conductor, SPC Center Conductor, PTFE Dielectric, Blue FEP Jacket, 50 Ω. Non-Magnetic.

feet
Add to Quote

The copper-tin composite outer conductor of EZFlex Formable™ Cable provides the same 100% coverage as solid-jacketed semi-rigid but is easily shaped to your dimensions by hand. Because of it’s dimensional similarities, these cables are used with standard semi-rigid cable connectors, providing similar electrical performance without the design and manufacturing complications.

See more:

Specifications

Dimensions

  • Center Conductor Diameter
    0.0360 in
  • Dielectric Diameter
    0.1170 in
  • Outer Conductor Diameter
    0.1410 in
  • Jacket Diameter
    0.1600 in

Materials

  • Center Conductor Material
    SPC
  • Dielectric Material
    PTFE
  • Outer Conductor Material
    Copper-Tin Composite
  • Jacket Material
    Blue FEP
  • RoHS Compliant
    Yes

Mechanical Characteristics

  • Minimum Temperature
    −55 °C
  • Maximum Temperature
    +200 °C
  • Inside Bend Radius (Minimum)
    0.375 in
  • Weight
    2.10 lbs
    per 100 ft

Electrical Characteristics

  • Nominal Impedance
    50.0 Ω
  • Nominal Impedance Margin
    ±1.0 Ω
  • Velocity of Propagation
    70.00%
  • Shielding Effectiveness
    >90 db
  • Voltage Withstanding
    5000 VRMS
    @ 60 Hz
  • Continuous Working Voltage
    2000 VRMS
    max
  • Maximum Operating Frequency
    34 GHz
Attenuation
Frequencydb / 100 Ft Typical
0.5 GHz
8.4 db
1.0 GHz
12.2 db
5.0 GHz
30 db
10.0 GHz
46 db
18.0 GHz
67.6 db
26.5 GHz
87.2 db
Power
FrequencyWatts CW @ 20 °C (Max)
0.5 GHz
600 W
1.0 GHz
450 W
5.0 GHz
180 W
10.0 GHz
120 W
18.0 GHz
73 W
26.5 GHz
70 W
Attenuation
Frequencydb / 100 Ft Typical
0.5 GHz
8.4 db
1.0 GHz
12.2 db
5.0 GHz
30 db
10.0 GHz
46 db
18.0 GHz
67.6 db
26.5 GHz
87.2 db
Power
FrequencyWatts CW @ 20 °C (Max)
0.5 GHz
600 W
1.0 GHz
450 W
5.0 GHz
180 W
10.0 GHz
120 W
18.0 GHz
73 W
26.5 GHz
70 W
.141 Coaxial Cable – 50 Ω Formable Jacketed Copper-Tin Composite – Non-Magnetic
feet
Add to Quote