Skip to main content
.047 Coaxial Cable – 50 Ω Formable Copper-Tin Composite

EZ-FLEX.47

© EZ Form Cable Inc. All rights reserved.

⌀.047" Formable Copper-Tin Composite Outer Conductor, SPCW Center Conductor, PTFE Dielectric, 50 Ω.

Specifications

Dimensions

  • Center Conductor Diameter
    0.0113 in
  • Dielectric Diameter
    0.0340 in
  • Outer Conductor Diameter
    0.0470 in

Materials

  • Center Conductor Material
    SPCW
  • Dielectric Material
    PTFE
  • Outer Conductor Material
    Copper-Tin Composite
  • RoHS Compliant
    Yes

Mechanical Characteristics

  • Minimum Temperature
    −55 °C
  • Maximum Temperature
    +200 °C
  • Inside Bend Radius (Minimum)
    0.125 in
  • Weight
    0.47 lbs
    per 100 ft

Electrical Characteristics

  • Nominal Impedance
    50.0 Ω
  • Nominal Impedance Margin
    ±2.0 Ω
  • Velocity of Propagation
    70.00%
  • Shielding Effectiveness
    >90 db
  • Voltage Withstanding
    2000 VRMS
    @ 60 Hz
  • Continuous Working Voltage
    800 VRMS
    max
  • Maximum Operating Frequency
    116 GHz
Attenuation
Frequencydb / 100 Ft Typical
0.5 GHz
30.2 db
1.0 GHz
42.9 db
5.0 GHz
98.3 db
10.0 GHz
141.5 db
18.0 GHz
193.6 db
26.5 GHz
225 db
40.0 GHz
286 db
50.0 GHz
328 db
65.0 GHz
385 db
90.0 GHz
470 db
Power
FrequencyWatts CW @ 20 °C (Max)
0.5 GHz
45 W
1.0 GHz
31 W
5.0 GHz
13 W
10.0 GHz
9.3 W
18.0 GHz
7 W
26.5 GHz
5.6 W
40.0 GHz
4.4 W
50.0 GHz
4 W
65.0 GHz
3.4 W
90.0 GHz
2.8 W

.047 Coaxial Cable – 50 Ω Formable Copper-Tin Composite

EZ-FLEX.47

⌀.047" Formable Copper-Tin Composite Outer Conductor, SPCW Center Conductor, PTFE Dielectric, 50 Ω.

feet
Add to Quote

The copper-tin composite outer conductor of EZFlex Formable™ Cable provides the same 100% coverage as solid-jacketed semi-rigid but is easily shaped to your dimensions by hand. Because of it’s dimensional similarities, these cables are used with standard semi-rigid cable connectors, providing similar electrical performance without the design and manufacturing complications.

Specifications

Dimensions

  • Center Conductor Diameter
    0.0113 in
  • Dielectric Diameter
    0.0340 in
  • Outer Conductor Diameter
    0.0470 in

Materials

  • Center Conductor Material
    SPCW
  • Dielectric Material
    PTFE
  • Outer Conductor Material
    Copper-Tin Composite
  • RoHS Compliant
    Yes

Mechanical Characteristics

  • Minimum Temperature
    −55 °C
  • Maximum Temperature
    +200 °C
  • Inside Bend Radius (Minimum)
    0.125 in
  • Weight
    0.47 lbs
    per 100 ft

Electrical Characteristics

  • Nominal Impedance
    50.0 Ω
  • Nominal Impedance Margin
    ±2.0 Ω
  • Velocity of Propagation
    70.00%
  • Shielding Effectiveness
    >90 db
  • Voltage Withstanding
    2000 VRMS
    @ 60 Hz
  • Continuous Working Voltage
    800 VRMS
    max
  • Maximum Operating Frequency
    116 GHz
Attenuation
Frequencydb / 100 Ft Typical
0.5 GHz
30.2 db
1.0 GHz
42.9 db
5.0 GHz
98.3 db
10.0 GHz
141.5 db
18.0 GHz
193.6 db
26.5 GHz
225 db
40.0 GHz
286 db
50.0 GHz
328 db
65.0 GHz
385 db
90.0 GHz
470 db
Power
FrequencyWatts CW @ 20 °C (Max)
0.5 GHz
45 W
1.0 GHz
31 W
5.0 GHz
13 W
10.0 GHz
9.3 W
18.0 GHz
7 W
26.5 GHz
5.6 W
40.0 GHz
4.4 W
50.0 GHz
4 W
65.0 GHz
3.4 W
90.0 GHz
2.8 W
Attenuation
Frequencydb / 100 Ft Typical
0.5 GHz
30.2 db
1.0 GHz
42.9 db
5.0 GHz
98.3 db
10.0 GHz
141.5 db
18.0 GHz
193.6 db
26.5 GHz
225 db
40.0 GHz
286 db
50.0 GHz
328 db
65.0 GHz
385 db
90.0 GHz
470 db
Power
FrequencyWatts CW @ 20 °C (Max)
0.5 GHz
45 W
1.0 GHz
31 W
5.0 GHz
13 W
10.0 GHz
9.3 W
18.0 GHz
7 W
26.5 GHz
5.6 W
40.0 GHz
4.4 W
50.0 GHz
4 W
65.0 GHz
3.4 W
90.0 GHz
2.8 W
.047 Coaxial Cable – 50 Ω Formable Copper-Tin Composite
feet