Skip to main content
.141 Coaxial Cable – 35 Ω Semi-Rigid Tin-Plated Copper – Non-Magnetic, Special Impedance

EZ-141-35-TP

© EZ Form Cable Inc. All rights reserved.

⌀.141" Semi-Rigid Tin-Plated Copper Outer Conductor, SPC Center Conductor, PTFE Dielectric, 35 Ω. Non-Magnetic, Special Impedance.

Specifications

Dimensions

  • Center Conductor Diameter
    0.0508 in
  • Dielectric Diameter
    0.1170 in
  • Outer Conductor Diameter
    0.1410 in

Materials

  • Center Conductor Material
    SPC
  • Dielectric Material
    PTFE
  • Outer Conductor Material
    Copper
  • Outer Conductor Plating Material
    Tin
  • RoHS Compliant
    Yes

Mechanical Characteristics

  • Minimum Temperature
    −55 °C
  • Maximum Temperature
    +125 °C
  • Inside Bend Radius (Minimum)
    0.188 in
  • Weight
    4.00 lbs
    per 100 ft

Electrical Characteristics

  • Nominal Impedance
    35.0 Ω
  • Nominal Impedance Margin
    ±1.5 Ω
  • Velocity of Propagation
    69.50%
  • Shielding Effectiveness
    >165 db
  • Voltage Withstanding
    3000 VRMS
    @ 60 Hz
  • Continuous Working Voltage
    1000 VRMS
    max
  • Maximum Operating Frequency
    31 GHz
Attenuation
Frequencydb / 100 Ft Typical
0.5 GHz
8.6 db
1.0 GHz
12.4 db
5.0 GHz
30.9 db
10.0 GHz
47.1 db
18.0 GHz
68.6 db
26.5 GHz
88.9 db
Power
FrequencyWatts CW @ 20 °C (Max)
0.5 GHz
552 W
1.0 GHz
385 W
5.0 GHz
161 W
10.0 GHz
110 W
18.0 GHz
77 W
26.5 GHz
62 W

.141 Coaxial Cable – 35 Ω Semi-Rigid Tin-Plated Copper – Non-Magnetic, Special Impedance

EZ-141-35-TP

⌀.141" Semi-Rigid Tin-Plated Copper Outer Conductor, SPC Center Conductor, PTFE Dielectric, 35 Ω. Non-Magnetic, Special Impedance.

feet
Add to Quote

EZ Form manufactures a broad range special impedance semi-rigid cables. Many are available off-the-shelf and custom values are available upon request.

To impede oxidation, we recommend keeping this product in its original packaging and storing it in a dry temperature controlled environment until consumed.

See more:

Specifications

Dimensions

  • Center Conductor Diameter
    0.0508 in
  • Dielectric Diameter
    0.1170 in
  • Outer Conductor Diameter
    0.1410 in

Materials

  • Center Conductor Material
    SPC
  • Dielectric Material
    PTFE
  • Outer Conductor Material
    Copper
  • Outer Conductor Plating Material
    Tin
  • RoHS Compliant
    Yes

Mechanical Characteristics

  • Minimum Temperature
    −55 °C
  • Maximum Temperature
    +125 °C
  • Inside Bend Radius (Minimum)
    0.188 in
  • Weight
    4.00 lbs
    per 100 ft

Electrical Characteristics

  • Nominal Impedance
    35.0 Ω
  • Nominal Impedance Margin
    ±1.5 Ω
  • Velocity of Propagation
    69.50%
  • Shielding Effectiveness
    >165 db
  • Voltage Withstanding
    3000 VRMS
    @ 60 Hz
  • Continuous Working Voltage
    1000 VRMS
    max
  • Maximum Operating Frequency
    31 GHz
Attenuation
Frequencydb / 100 Ft Typical
0.5 GHz
8.6 db
1.0 GHz
12.4 db
5.0 GHz
30.9 db
10.0 GHz
47.1 db
18.0 GHz
68.6 db
26.5 GHz
88.9 db
Power
FrequencyWatts CW @ 20 °C (Max)
0.5 GHz
552 W
1.0 GHz
385 W
5.0 GHz
161 W
10.0 GHz
110 W
18.0 GHz
77 W
26.5 GHz
62 W
Attenuation
Frequencydb / 100 Ft Typical
0.5 GHz
8.6 db
1.0 GHz
12.4 db
5.0 GHz
30.9 db
10.0 GHz
47.1 db
18.0 GHz
68.6 db
26.5 GHz
88.9 db
Power
FrequencyWatts CW @ 20 °C (Max)
0.5 GHz
552 W
1.0 GHz
385 W
5.0 GHz
161 W
10.0 GHz
110 W
18.0 GHz
77 W
26.5 GHz
62 W
.141 Coaxial Cable – 35 Ω Semi-Rigid Tin-Plated Copper – Non-Magnetic, Special Impedance
feet
Add to Quote
EZ Form Cable
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.