Skip to main content
.25 Coaxial Cable – 50 Ω Semi-Rigid Tin-Lead-Plated Aluminum – Air-Spaced, Non-Magnetic

EZ-250-AL-AS-TL

© EZ Form Cable Inc. All rights reserved.

⌀.25" Semi-Rigid Tin-Lead-Plated Aluminum Outer Conductor, SPC Center Conductor, AS PTFE Dielectric, 50 Ω. Air-Spaced, Non-Magnetic.

Specifications

Dimensions

  • Center Conductor Diameter
    0.0740 in
  • Dielectric Diameter
    0.2090 in
  • Outer Conductor Diameter
    0.2500 in

Materials

  • Center Conductor Material
    SPC
  • Dielectric Material
    AS PTFE
  • Outer Conductor Material
    Aluminum
  • Outer Conductor Plating Material
    Tin-Lead
  • RoHS Compliant
    No

Mechanical Characteristics

  • Minimum Temperature
    −55 °C
  • Maximum Temperature
    +200 °C
  • Inside Bend Radius (Minimum)
    0.750 in
  • Weight
    5.50 lbs
    per 100 ft

Electrical Characteristics

  • Nominal Impedance
    50.0 Ω
  • Nominal Impedance Margin
    ±1.0 Ω
  • Velocity of Propagation
    78.00%
  • Shielding Effectiveness
    >165 db
  • Voltage Withstanding
    5000 VRMS
    @ 60 Hz
  • Continuous Working Voltage
    3000 VRMS
    max
  • Maximum Operating Frequency
    20 GHz
Attenuation
Frequencydb / 100 Ft Typical
0.5 GHz
4 db
1.0 GHz
5.9 db
5.0 GHz
14 db
10.0 GHz
22.2 db
18.0 GHz
32.2 db
Power
FrequencyWatts CW @ 20 °C (Max)
0.5 GHz
2100 W
1.0 GHz
1700 W
5.0 GHz
580 W
10.0 GHz
380 W
18.0 GHz
270 W
26.5 GHz
255 W

.25 Coaxial Cable – 50 Ω Semi-Rigid Tin-Lead-Plated Aluminum – Air-Spaced, Non-Magnetic

EZ-250-AL-AS-TL

⌀.25" Semi-Rigid Tin-Lead-Plated Aluminum Outer Conductor, SPC Center Conductor, AS PTFE Dielectric, 50 Ω. Air-Spaced, Non-Magnetic.

feet
Add to Quote

EZ Form aluminum jacketed semi-rigid AS (Air Spaced) cables feature a “Profile-extruded” PTFE dielectric, that consists of six equidistant diameters that are extruded along the length of the dielectric core, introducing air, thereby changing the dielectric constant and improving the velocity of propagation. This feature facilitates lower attenuation and higher operating temperatures compared to solid PTFE semi-rigid cables. Aluminum Jacketed cables have the added advantage of being 40% lighter than their copper jacketed equivalents.

To avoid oxidation, we recommend keeping this product in its original packaging and storing it in a dry temperature controlled environment until consumed.

See more:

Specifications

Dimensions

  • Center Conductor Diameter
    0.0740 in
  • Dielectric Diameter
    0.2090 in
  • Outer Conductor Diameter
    0.2500 in

Materials

  • Center Conductor Material
    SPC
  • Dielectric Material
    AS PTFE
  • Outer Conductor Material
    Aluminum
  • Outer Conductor Plating Material
    Tin-Lead
  • RoHS Compliant
    No

Mechanical Characteristics

  • Minimum Temperature
    −55 °C
  • Maximum Temperature
    +200 °C
  • Inside Bend Radius (Minimum)
    0.750 in
  • Weight
    5.50 lbs
    per 100 ft

Electrical Characteristics

  • Nominal Impedance
    50.0 Ω
  • Nominal Impedance Margin
    ±1.0 Ω
  • Velocity of Propagation
    78.00%
  • Shielding Effectiveness
    >165 db
  • Voltage Withstanding
    5000 VRMS
    @ 60 Hz
  • Continuous Working Voltage
    3000 VRMS
    max
  • Maximum Operating Frequency
    20 GHz
Attenuation
Frequencydb / 100 Ft Typical
0.5 GHz
4 db
1.0 GHz
5.9 db
5.0 GHz
14 db
10.0 GHz
22.2 db
18.0 GHz
32.2 db
Power
FrequencyWatts CW @ 20 °C (Max)
0.5 GHz
2100 W
1.0 GHz
1700 W
5.0 GHz
580 W
10.0 GHz
380 W
18.0 GHz
270 W
26.5 GHz
255 W
Attenuation
Frequencydb / 100 Ft Typical
0.5 GHz
4 db
1.0 GHz
5.9 db
5.0 GHz
14 db
10.0 GHz
22.2 db
18.0 GHz
32.2 db
Power
FrequencyWatts CW @ 20 °C (Max)
0.5 GHz
2100 W
1.0 GHz
1700 W
5.0 GHz
580 W
10.0 GHz
380 W
18.0 GHz
270 W
26.5 GHz
255 W
.25 Coaxial Cable – 50 Ω Semi-Rigid Tin-Lead-Plated Aluminum – Air-Spaced, Non-Magnetic
feet
Add to Quote