This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
.07 Coaxial Cable – Semi-Rigid Tin-Plated Copper – Low-Loss
EZ-70-LA-TP
© EZ Form Cable Inc. All rights reserved.
⌀.07" Semi-Rigid Tin-Plated Copper Outer Conductor, SPC Center Conductor, LD PTFE Dielectric. Low-Loss.

Specifications
Dimensions
-
Center Conductor Diameter0.0201 in
-
Dielectric Diameter0.0590 in
-
Outer Conductor Diameter0.0700 in
Materials
-
Center Conductor MaterialSPC
-
Dielectric MaterialLD PTFE
-
Outer Conductor MaterialCopper
-
Outer Conductor Plating MaterialTin
-
RoHS CompliantYes
Mechanical Characteristics
-
Minimum Temperature−55 °C
-
Maximum Temperature+250 °C
-
Inside Bend Radius (Minimum)0.250 in
-
Weight0.77 lbsper 100 ft
Electrical Characteristics
-
Nominal Impedance50.0 Ω
-
Nominal Impedance Margin±2.0 Ω
-
Velocity of Propagation76.50%
-
Shielding Effectiveness>165 db
-
Voltage Withstanding2500 VRMS@ 60 Hz
-
Continuous Working Voltage1000 VRMSmax
-
Maximum Operating Frequency72 GHz
Attenuation
Frequency | db / 100 Ft Typical |
---|---|
0.5 GHz | 13.2 db |
1.0 GHz | 18.6 db |
5.0 GHz | 42 db |
10.0 GHz | 60 db |
18.0 GHz | 81 db |
26.5 GHz | 99 db |
40.0 GHz | 123 db |
50.0 GHz | 138.8 db |
65.0 GHz | 160 db |
Power
.07 Coaxial Cable – Semi-Rigid Tin-Plated Copper – Low-Loss
EZ-70-LA-TP
⌀.07" Semi-Rigid Tin-Plated Copper Outer Conductor, SPC Center Conductor, LD PTFE Dielectric. Low-Loss.

EZ Form copper jacketed semi-rigid LA (Low Attenuation) cables feature a microporous dielectric, that facilitates lower attenuation, higher operating temperatures and greater phase stability vs. temperature when compared to solid PTFE semi-rigid cables.
To avoid oxidation, we recommend keeping this product in its original packaging and storing it in a dry temperature controlled environment until consumed.
Additional information unique to microporous dielectrics:
Phase Vs. Temperature
Attenuation Vs. Temperature
See more:
Specifications
Dimensions
-
Center Conductor Diameter0.0201 in
-
Dielectric Diameter0.0590 in
-
Outer Conductor Diameter0.0700 in
Materials
-
Center Conductor MaterialSPC
-
Dielectric MaterialLD PTFE
-
Outer Conductor MaterialCopper
-
Outer Conductor Plating MaterialTin
-
RoHS CompliantYes
Mechanical Characteristics
-
Minimum Temperature−55 °C
-
Maximum Temperature+250 °C
-
Inside Bend Radius (Minimum)0.250 in
-
Weight0.77 lbsper 100 ft
Electrical Characteristics
-
Nominal Impedance50.0 Ω
-
Nominal Impedance Margin±2.0 Ω
-
Velocity of Propagation76.50%
-
Shielding Effectiveness>165 db
-
Voltage Withstanding2500 VRMS@ 60 Hz
-
Continuous Working Voltage1000 VRMSmax
-
Maximum Operating Frequency72 GHz
Attenuation
Frequency | db / 100 Ft Typical |
---|---|
0.5 GHz | 13.2 db |
1.0 GHz | 18.6 db |
5.0 GHz | 42 db |
10.0 GHz | 60 db |
18.0 GHz | 81 db |
26.5 GHz | 99 db |
40.0 GHz | 123 db |
50.0 GHz | 138.8 db |
65.0 GHz | 160 db |
Power
Attenuation
Frequency | db / 100 Ft Typical |
---|---|
0.5 GHz | 13.2 db |
1.0 GHz | 18.6 db |
5.0 GHz | 42 db |
10.0 GHz | 60 db |
18.0 GHz | 81 db |
26.5 GHz | 99 db |
40.0 GHz | 123 db |
50.0 GHz | 138.8 db |
65.0 GHz | 160 db |
Power
.07 Coaxial Cable – Semi-Rigid Tin-Plated Copper – Low-Loss